Ball Valves

K 83 TW - fully welded ball valve

  • water, gas, petroleum, acid working medium
  • flanged or welded connection
  • range of working temperatures from -60°C to +200°C
  • CLASS 150 – 1500, NPS 2″ – 56″

K 83 TB - bolted ball valve

  • water, gas, petroleum, acid working medium
  • flanged or welded connection
  • range of working temperatures from -60°C to +200°C
  • CLASS 150 – 2500, NPS 2″ – 56″

K 89 - metal ball valve

  • media with high temperatures and abrasive media
  • flanged or welded connection
  • range of working temperatures from -29°C to +550°C
  • CLASS 150 – 600, NPS 2″ – 22″

K 88 - cryogenic ball valve

  • liquefied gas media
  • flanged or welded connection
  • range of working temperatures from -30°C to -196°C
  • CLASS 150 – 900, NPS 2″ – 30″


Gate Valves

C 09.2 - cast steel gate valve

  • water, saturated steam, air, oil, crude petroleum and petroleum products, nonaggressive fluids
  • flanged or welded connection
  • range of working temperatures from -60°C to +650°C
  • CLASS 150 – 1500, NPS 2″ – 56″

C 09.2 - cryogenic gate valve

  • liquefied gas and liquefied LNG
  • flanged or welded connection
  • range of working temperatures from -196°C to +538°C
  • CLASS 150 – 1500, NPS 2″ – 12″

S 38 - cast steel gate valve

  • water, steam, air, oil, petroleum and petroleum products, nonaggressive fluids
  • flanged or welded connection
  • range of working temperatures from -60°C to +550°C
  • PN 16 – 100, DN 50 – 1000

S 85.1 - cast steel slab gate valve

  • petroleum and petroleum products
  • flanged or welded connection
  • range of working temperatures from -60°C to +50°C
  • PN 16 – 160, DN 300 – 1200

S 85.2 - welded body slab gate valve

  • petroleum and petroleum products
  • flanged or welded connection
  • range of working temperatures from -60°C to +80°C
  • CLASS 150 – 300, NPS 12″ – 48″


Swing Check Valves

C 09 - cast steel swing check valve

  • water, steam, oil, crude petroleum and petroleum products, nonaggressive fluids
  • flanged or welded connection
  • range of working temperatures from -46°C to +650°C
  • CLASS 150 – 600, NPS 2″ – 24″


Globe Valves

C 09.1 - cast steel globe valve

  • water, saturated steam, oil, crude petroleum and petroleum products, nonaggressive fluids
  • flanged or welded connection
  • range of working temperatures from -60°C to +650°C
  • CLASS 150 – 600, NPS 2″ – 14″


Valves For Nuclear Installations

A 00 - gate valve

  • water, steam, air, gas , oil, nonaggressive fluids
  • welded connection
  • working temperatures to + 350°C
  • working pressure up to 20,0 MPa
  • DN 50 – 800

A 41 - non-slam swing check valve

  • water, steam, air, gas, oil, nonaggressive fluids
  • welded connection
  • working temperatures to + 350°C
  • working pressure up to 20,0 MPa
  • DN 50 – 800

C 23 - swing check valve

  • water, steam, air, gas, oil, nonaggressive fluids
  • welded connection
  • working temperatures to + 350°C
  • working pressure up to 20,0 MPa
  • DN 50 – 600


MSA Valves Gallery



 

Multiphase Meter

The simplest and most effective multiphase meter in the market:

  • Non Radioactive solution
  • Real three-phase meter based on mass measurement techniques
  • Two methods of calculations converging to guarantee correct results
  • No need of PVT data information. Only densities are required
  • No flow conditioning requirement
  • It covers the whole range of flow regimes: 0-100% GVF & 0-100% WC without loss of accuracy




WELKER PRODUCTS

ALS Analyzer Liquid Shutoff

The Welker ALS Analyzer Liquid Shutoff prevents any liquid from entering your gas chromatograph, keeping the analyzer columns safe from damage and protecting sensitive equipment from expensive repairs.

Features

  • Fail-safe shutoff in the presence of liquids
  • Sight port for instant visual confirmation of flow status
  • Corrosion resistant material

Benefits

  • Optimizes profitability by protecting sensitive equipment from liquid damage
  • Quick and easy installation Simple maintenance.

F-4 and F-5

The Welker® F-4 and F-5 Filter/Dryers help to remove aerosols, odorant, and liquid hydrocarbons from gas or instrument air. Add a filter to help reduce line freezing, increase instrument performance, and cut down on maintenance. When the filter cartridge becomes saturated, it can easily be removed and replaced. The included standard cartridge contains silica gel (F-4) or a blend of silica gel and activated charcoal (F-5). Other media options are available to suit specialized applications. Supply clean, dry gas or air with the F-4 and F-5 Filter Dryers.

Key Features

  • Spin-on and off filter body simplifies cartridge swaps
  • Filter natural gas to use as an instrument supply source
  • Helps remove water, aerosols, liquid hydrocarbons, sulfur, or odorant based on media selected

IRA-4SS

The Welker® IRA-4SS Probe Regulator is designed to regulate a gas sample stream to an analyzer without interrupting pipeline flow. With AI Control™, the probe automatically inserts and retracts using pipeline pressure.

Features

  • Provides properly conditioned sample stream Insert and retract probe at full pipeline pressure
  • Easily adjustable to multiple insertion depths
  • Point of regulation occurs at the tip of the probe in the flowing stream
  • Probe design inhibits creation of free liquids and mitigates the Joule-Thomson effect
  • Diaphragm design for optimizing low-pressure output sensitivity

Benefits

  • Proven safety with AI Control™ provides peace of mind Reduces line pack for analyzer applications
  • Probe retraction design allows maintenance to be performed during continuous pipeline operation
  • Design allows for easy installation and intuitive operation
  • Transferable from location to location

LE-2SS

The Welker LE-2SS Liquid Eliminator is designed to protect analyzers from damage and contamination by removing liquids from gas samples.

Key Features

  • Integrated liquid and sediment filtration
  • Liquid-eliminating chamber
  • Self-draining design
  • Optional Knock-Out Probe™ for pipeline mount
  • Stainless steel construction

Benefits

  • Optimizes profitability by protecting sensitive equipment from liquid damage
  • Quick and easy installation
  • Simple maintenance

SCHS Sample Conditioning Heated System

The Welker® SCHS Sample Conditioning Heated System properly conditions a flowing gas stream and protects analyzers from free liquids.

 

Features

  • 3-stage protection system for analyzers
  • Pipeline-mounted system for analyzer grade conditioned gas
  • Liquid-eliminating probe assembly with integrated liquid and sediment filtration
  • Effective sample heat retention before point of regulation to mitigate the Joule-Thomson effect and prevent gas composition from being compromised
  • Fail-safe shutoff in the presence of liquid in the system
  • Modular design and removable insulated enclosure

Benefits

  • Analyzer is fortified by patented lines of protection
  • Properly conditioned gas sample for analysis
  • Effective protection against costly damage to analyzer
  • Compact footprint
  • Easy access to individual components for convenient maintenance

Insertion Regulator Probe (IRD-4SS)

The Welker®IRD-4SS is designed with the point of regulation near the tip of the probe in the flowing stream. The thermal fin technology mitigates the Joule-Thomson effect.

 

Features

  • Diaphragm design for increased low-pressure sensitivity
  • Inhibits creation of free liquids into instrument supply system

Specifications:

  • 316/316L Stainless Steel, Viton®, PTFE
  • 3600 psig MAOP @ -20 °F to 120 °F
  • Probe Lengths suitable for: 2”, 3”, 4”, 6”, 8”, 10”, 12” pipelines
  • 1/4” FNPT outlet connection
  • 3/4” MNPT pipeline connection